Operating Manual


Unit Testing

• A simple test can be performed to determine the fire flow of a given water source.

• In addition to the TurboDraft setup, connect a master stream device with a straight bore nozzle.

• See page 12 to determine the estimated fire flow for your location and required nozzle bore for deck gun.

• Place the TurboDraft unit in operation as shown in the TurboDraft Set-Up images.

• Once the water supply is established, start flowing water to the deck gun and continue to increase water flow to the deck gun until the 5 inch line from the TurboDraft starts to get soft. At this point you have reached the maximum flow.

• Read the pressure at the deck gun. Refer to Chart 3 below to determine the flow for the deck gun at that pressure.

Chart 3
GPM AT VARIOUS PRESSURES (PSIG)
Nozz. Dia.
30
35
40
45
50
55
60
66
70
76
80
85
90
95
100
105
110
115
120
1-1/8" 206 222 238 252 266 279 291 305 315 328 336 347 357 366 376 385 394 403 412
1-3/8" 308 332 355 377 397 417 435 456 470 490 502 518 533 547 562 575 589 602 615
1-1/2" 366 395 423 448 473 496 518 543 559 583 598 616 634 651 668 685 701 717 732