Strainer
Clearing
During
operation of the unit it may become necessary to clear the strainer
of grass or debris from the water source. This is easily performed
and should only take 15 to 30 seconds.
Discontinue
water supply operations by closing down all discharges from the
truck except for the line supplying the TurboDraft unit.
Open
the tank-to-pump valve.
Slowly
close the suction intake valve. This will cause the flow of water
to backup into the strainer and clear any obstructions from the
screen.
Keep
valve closed for 15 to 30 seconds to ensure the debris is cleared
from the strainer area.
Slowly
open the suction intake valve to re-establish the water supply.
Close tank-to-pump valve and open tank fill valve 1/4 to 1/2 and
refill tank.
When